膨胀型Salutan tahan api
KF-FR100 Intumescent Fire Retardant Paint
KF-FR100 intumescent fireproof coating uses APP/PER/MEL as the P-C-N intumescent flame retardant system. When exposed to fire, the coating expands 50-80 times to form a carbonized insulating layer that keeps the substrate temperature below the critical value. It is widely used for fire protection of combustible substrates such as wood/cables/plastics and steel structures.
ProductsGambaran
Intumescent fireproof coating is a special fireproof coating developed by KeXin New Material. Designed according to GB 14907 and ISO 834 standards, the coating expands in a fire to form a dense carbonized layer, effectively blocking heat conduction and buying valuable time for personnel evacuation and fire rescue.
The product has passed national fire protection 3C certification and UL international certification, with fire resistance limit of 1-3 hours. Suitable for steel structures, concrete structures, cables and other buildings and industrial facilities requiring passive fire protection.
Mengapa memilih salutan tahan api intumesen?
TerasAdvantages
P-C-N Intumescent Flame Retardant System
Sistem antinyala kembung klasik terdiri daripada ammonium polifosfat (APP/sumber asid) + pentaeritritol (PER/sumber karbon) + melamin (MEL/sumber gas). Apabila terdedah kepada api, APP membebaskan asid fosforik untuk mangkatalkan dehidrasi PER menjadi arang, dan MEL membebaskan gas lembam untuk mengembungkan lapisan karbon, membentuk lapisan penebat haba dengan kekonduksian terma<0.1W/(mK)的Thermal Insulation层。
Perlindungan api pelbagai substrat
Combustible building materials such as wood/plywood/density board. Fire protection for cables/cable trays. Steel structures (in combination with epoxy fireproof coating). Fire protection for plastic pipes and plastic products. Fireproof coating for tunnels and underground spaces.
Finishing Fire Protection · Both Aesthetics and Safety
Water-based intumescent fireproof coating forms a smooth white or color-adjustable coating after drying. Water-based topcoat can be applied for decoration without affecting fire performance. Suitable for indoor wooden structures and public spaces that require both fire protection and decorative effects.
Perkhidmatan teknikal sistem salutan profesional
Kexin boasts an experienced coatings R&D and application technology team, providing comprehensive services from substrate analysis, coating selection, and process parameter optimization to on-site application guidance. We work in conjunction with our clients' coating production lines to fine-tune coating application parameters, ensuring optimal coating quality and production efficiency.
Sistem pembuatan hijau patuh alam sekitar
All products are RoHS/REACH certified and meet national environmental standards for VOC content. Water-based and high-solids, low-VOC formulations are continuously iterated to meet increasingly stringent environmental protection requirements. Environmental performance test reports from authoritative third-party testing institutions such as SGS and CTI are provided.
Kawalan kualiti menyeluruh dan kebolehesanan kelompok
A comprehensive quality control system is in place from raw material intake to finished product delivery. Each batch of products undergoes rigorous physical and chemical performance testing and coating simulation testing. Batch numbers are fully traceable, allowing for tracking of raw material origins and production process data. Each product comes with a batch test report and product warranty certificate for customer peace of mind.
TeknikSpecifications
Parameter asas
Spesifikasi prestasi
The above technical parameters are from the testing data of Kexin New Materials Laboratory (ISO 17025 certified). Actual values may vary slightly due to construction environment and substrate conditions. For the latest technical data, please contact technical support to obtain the COA test report.
Sering DitanyaSoalan
ApplicationProcess
Penyediaan permukaan
Thoroughly clean the substrate to remove oil, rust, and oxide scale. Sandblast steel to Sa2.5 grade. Perform surface pretreatment according to product requirements to ensure the substrate is clean. Ambient temperature 5-40°C, relative humidity<85%。
Primer application
Pilih primer yang sepadan dengan sistem salutan dan substrat. Bancuh mengikut nisbah produk dan kawal ketebalan filem. Teruskan selepas primer kering. Pra-perkukuh kawasan kritikal.
Aplikasi salut utama
Carry out the main coating application according to process requirements. Strictly control construction parameters such as film thickness/environmental temperature and humidity/flash-off time. Ensure the coating is uniform and consistent with no sagging or pinholes. Manually pre-coat complex areas to ensure full coverage.
Curing process
Bake or air dry at room temperature until fully cured according to product requirements. Maintain a uniform oven temperature (±5°C) and gradually increase the temperature to avoid coating defects. For room temperature curing, ensure adequate ventilation and suitable humidity.
Inspection and Acceptance
Test film thickness, adhesion, gloss, color difference, chemical resistance, and other indicators. Conduct comprehensive performance testing according to relevant standards. Upon successful completion of all tests, issue a test report and quality assurance certificate, and ship in dust-free packaging.
AplikasiKes

Semburan salutan tahan api struktur kayu
Semburan salutan intumesen pada struktur kayu dalaman — kelas kalis api B1.

Aplikasi salutan tahan api pada kabel
Sapuan salutan intumesen pada dulang kabel menghalang api merambat sepanjang kabel

Kerja salutan tahan api struktur keluli
Perlindungan api intumesen semburan pada struktur keluli dalaman

Salutan tahan api papan lapis
Rawatan api intumesen rol pada papan lapis hiasan dalaman

Aplikasi salutan tahan api terowong
Perlindungan api intumesen semburan pada lapisan dalam terowong

Salutan tahan api untuk ruang awam
Aplikasi salutan intumesen pada permukaan hiasan kayu di ruang awam

Salutan untuk pintu api kayu
Salutan intumesen pada pintu api kayu — produk diperakui kawalan api

Salutan tahan api paip plastik
Salutan intumesen pada paip plastik menyekat rambatan api

Salutan tahan api teater
Salutan intumesen pada struktur kayu pentas teater

Salutan tahan api hotel
Salutan tahan api pada hiasan kayu di kawasan awam hotel

Salutan tahan api dewan pameran
Kerja salutan tahan api struktur kayu dewan pameran demi keselamatan kebakaran

Salutan tahan api bangunan bersejarah
Salutan tahan api lutsinar pada struktur kayu purba melindungi khazanah warisan
Salutan berkaitanProduk disyorkan

Salutan tahan api struktur keluli
Intumescent · 3h fire resistance · 3C certified
Ketahui lebih lanjut→
Perlindungan api luaran filem tebal struktur keluli
Thick-film steel structure · Outdoor fireproofing · Durable
Ketahui lebih lanjut→
Salutan tahan api terowong
Tunnel-specific · HC standard · 2h fire resistance
Ketahui lebih lanjut→
Salutan tahan api kabel
Cable fireproofing · V0 grade · Flame retardant and arc resistant
Ketahui lebih lanjut→Intumescent Fireproof Coating·Terus dari kilang
Kexin membekalkan salutan tahan api intumesen terus dari kilang sumber. Ujian sampel percuma, bimbingan jurutera di tapak, jaminan kualiti diperakui ISO.
artikel & berita berkaitan
Bacaan lanjut: artikel teknikal dan berita industri Kexin New Materials
- Cat nano penebat dan tahan api untuk pakej bateri kenderaan elektrik: Penyelesaian perlindungan menyeluruh daripada mekanisme penyebaran kehilangan kawalan terma kepada sistem penebat nano dan tahan api
- Cat api kalis api untuk struktur keluli — sistem jenis mengembang dan tidak mengembang
- Sistem salutan rel pengangkutan dan standard keselamatan
- Mekanisme Pembakaran Berpengembangan dan Penahanan Api bagi Cat Tahan Api serta Aplikasi Kejuruteraannya
- Berita industri