Home / Products / Industrial Coatings / Antistatic epoxy floor
Static electricity protection and safety assurance

Antistaticepoxy flooring

KF-AS500 Anti-Static Epoxy Floor

KeXin KF-AS500 Anti-Static Epoxy Floor Coating incorporates special conductive fillers (conductive carbon fiber/conductive mica/metal powder) into the epoxy self-leveling system, giving the coating stable and lasting static dissipation capability. A supporting embedded grounding copper foil grid system safely directs static electricity into the ground. It is widely used in precision manufacturing and working environments that are electrostatic-sensitive (ESDS) and require ESD protection, such as electronic component manufacturing, semiconductor packaging, SMT placement, data centers, and military explosive ordnance workshops.

10⁶Ω
Surface resistance range
导电网络
Embedded copper-foil grounding
ESDCertifications
IEC 61340 Standard
3mm
Self-leveling thickness
永久Antistatic
no attenuation, no failure
80MPa+
Compressive strength
Full Systemcompatible
Conductive Primer + Conductive Topcoat
20kg
Standard packaging
SourceFactory
Customized technical solution

ProductsOverview

Anti-Static Epoxy Flooring is a high-performance industrial floor coating developed by KeXin New Material. It offers excellent wear resistance, pressure resistance, and chemical resistance. It is widely used for floor decoration and protection in industrial plants, underground garages, commercial spaces, and other locations.

After construction, the floor is seamless, easy to clean, beautiful and durable, with a design service life of over 10 years. Different functional models such as anti-slip, anti-static, and heavy-duty anti-corrosion can be selected according to usage requirements. KeXin provides free floor survey and scheme design services.

Why choose antistatic epoxy flooring?

✓
ISO-certified factory · direct from the manufacturer——End-to-end quality control from raw material to finished product, no trader margin
✓
Free sample testing · quality you can see——Samples from 1 kg, supplied with TDS and MSDS documentation
✓
On-site engineer guidance——Free on-site service in the Pearl River Delta region, remote technical support elsewhere
✓
Fast dispatch within 48 hours——Standard products well stocked; custom orders in 3-7 working days
✓
Complete coating system solutions——Primer / midcoat / topcoat systems designed as a matched set, one-stop procurement
✓
RoHS / REACH environmental compliance——Tested by third-party laboratories SGS/CTI, exported to 50+ countries

CoreAdvantages

Stable electrostatic dissipation

Conductive fillers form a continuous three-dimensional conductive network within the coating. Surface resistance is stably controlled at 10⁶-10⁹Ω (static dissipative type) or<10⁶Ω(Static-dissipative type)Range内。electrical resistance值不受空气Humidity变化影响长期稳定不衰减。passedIEC 61340-5-1国际electrostatic protectionStandard和SJ/T 10694中国ElectronicsProductsAntistaticTestingCertifications。

Embedded copper-foil static-dissipation grid system

A dedicated conductive primer combined with an embedded grounding copper foil grid (spacing 3-6m) forms a complete static dissipation pathway. Static charges generated by personnel and mobile equipment are safely directed to ground through the path of coating surface → conductive primer → copper foil grid → grounding terminal. System grounding resistance<10ΩEnsures静电泄放畅通无阻。

Full performance set of epoxy self-leveling

On the basis of anti-static function, it possesses all the excellent properties of epoxy self-leveling flooring. Mirror-like self-leveling, seamless and easy to clean, wear-resistant and compressive strength ≥80MPa, chemical corrosion resistant, Grade 0 anti-mold and antibacterial. One flooring system simultaneously meets the four functional requirements of anti-static, cleanroom, wear-resistant, and anti-corrosion, making it the best choice for electronic cleanroom facilities.

Resistant to chemical cleaners and disinfectants

Electronic cleanrooms require daily wiping and cleaning with solvents such as isopropyl alcohol, acetone, and deionized water. The coating has good tolerance to commonly used electronic industry cleaning agents and disinfectants. Repeated wiping will not cause resistance values to increase or coating damage. The surface is smooth and non-porous with no particle shedding, avoiding contamination of the cleanroom environment.

Permanent Anti-Static · No Degradation

Unlike surface-applied anti-static liquids (which require reapplication every 3-6 months), conductive fillers are built into the entire coating thickness. Even if slight surface wear exposes new coating surface, the same static dissipative performance is maintained. The anti-static function lasts as long as the coating itself, permanently effective with no post-maintenance required.

Complete antistatic flooring system

Provides a full-process anti-static flooring solution from on-site survey, grounding system design, material matching, to construction acceptance. A complete system including conductive primer, conductive mortar leveling layer, conductive copper foil, grounding terminals, and anti-static topcoat. Professional construction teams strictly follow ESD standards for construction and point-to-point resistance testing acceptance.

TechnicalSpecifications

Basic parameters

Product typeTwo-component antistatic epoxy self-leveling
antistatic typeStatic dissipative type (10⁶-10⁹Ω)/Conductive type (<10⁶Ω)
Mix ratio (by weight)A:B = 4:1
Solids content≥95%
VOC content<50g/L
Recommended thickness2-3mm (self-leveling trowel application)
surface dry/hard dry(25°C)8h / 24h
Packaging Specs20 kg/kit(A16kg+B4kg)

Performance

surface resistance10⁶-10⁹Ω (dissipative type)/<10⁶Ω(导电type)
system grounding resistance<10Ω
Compressive strength≥80 MPa
Pencil hardness≥3H
Taber abrasion (CS-17/1000g)<60mg/1000转
Adhesion (pull-off method)≥3 MPa
Resistance to 10% sulfuric acid (30d)Surface resistance change rate<20%
Resistance to IPA wiping (200 cycles)Surface resistance change rate<15%

The technical parameters above are taken from test data of the Kexin New Materials laboratory (ISO 17025 accredited); actual values may differ slightly depending on application conditions and substrate. Please contact technical support to obtain a current COA test report.

Frequently AskedFAQ

Which substrates and scenarios does it suit?+
Suitable for many common substrates, including steel, concrete, wood and plastics. Widely used in industrial manufacturing, architectural decoration, automotive and transport, furniture and home furnishings. For professional selection advice, call 400-901-0757.
What is the application method?+
Apply by conventional spray, brush or roller. Substrate must be clean, dry and grease-free. Ambient temperature 5-35°C, relative humidity <85% 为BestApplicationConditions。SpecificParameters — see Products TDS Technical Data Sheet。
Which primer or topcoat completes the system?+
We recommend using a matching primer and topcoat from the same Kexin series to secure system compatibility and best performance. A Kexin engineer can design a complete primer-midcoat-topcoat system for your specific service conditions, free of charge.
How to get samples and a quote?+
Free samples of standard products are provided (freight at the customer's cost), supplied with TDS and MSDS documentation. For bulk purchases please contact 400-901-0757 or 13531350189. Sample quantity from 1 kg; bulk orders from 20 kg.
How do I pick the right grade for my operating conditions?+
Choosing a coating product requires considering the substrate type, the service environment (temperature / humidity / chemical media), the required corrosion protection class (ISO 12944 C1-C5M), the application conditions and the budget. We recommend contacting our technical engineer on 400-901-0757 for professional selection advice; free trial spraying and test verification are supported.
What is the MOQ and lead time?+
Samples from 1 kg; regular products from 20 kg per batch. Stock items ship within 48 hours, made-to-order products in 3-7 working days. Door delivery can be arranged within the Pearl River Delta region.

ApplicationProcess

1

Substrate preparation

Grind or shot-blast the concrete floor to remove laitance. Fill cracks and holes with conductive repair mortar. Substrate moisture content<8%强度≥C25。按Design图纸预放copper-foil grid位置线。清理灰尘后用Industrial吸尘器彻底吸净。

2

Copper-foil grid laying

Install self-adhesive copper foil grid at 3-6m spacing. Solder the copper foil intersections to ensure electrical continuity. Lead out one end of the copper foil grid and connect to the building grounding terminal or an independent grounding electrode. Measure the grounding resistance before roller-applying the conductive primer to cover the copper foil grid<10Ω。

3

Conductive primer application

Apply one uniform roller coat of conductive primer to cover the copper foil grid. The primer must completely cover the copper foil and firmly bond to the substrate. After the primer dries, perform an initial resistance test to ensure the conductive continuity of the primer layer. Measure the resistance to ground in each area separately and keep data records.

4

Antistatic topcoat application

Trowel anti-static epoxy self-leveling topcoat to the design thickness of 2-3mm. During application, strictly monitor that the copper foil grid is not displaced or damaged. After the topcoat is completed, use a defoaming roller to remove air bubbles. Construction ambient temperature 15-30°C relative humidity<75%。

5

System testing and acceptance

After the topcoat is fully cured for 7 days, perform system testing according to IEC 61340 standard. Use a 100V test voltage to measure the resistance between any two points (RTT) and point-to-ground resistance (RTG). No fewer than 5 measurement points per measurement area. After all pass, issue an anti-static floor system acceptance report.

ApplicationsCases

芯片制造无尘车间防静电

Antistatic protection for chip fab cleanrooms

Antistatic epoxy self-leveling flooring for semiconductor chip cleanrooms — protecting ESD-sensitive precision manufacturing

SMT贴片车间防静电地坪

Anti-Static Floor for SMT Placement Workshop

Antistatic epoxy flooring for electronic SMT lines — ESD protection for surface-mount technology

数据中心防静电地坪

Data center antistatic flooring

Antistatic epoxy flooring for large data center server rooms, ensuring safe ESD operation of precision electronic equipment

军工厂火工品车间

Military ordnance workshops

Static-dissipative epoxy flooring for military ordnance assembly workshops — strict electrostatic safety in flammable and explosive environments

医疗器械电子车间

Medical device electronics workshops

Antistatic epoxy flooring for medical device electronic component production — certified environment to ISO 13485 quality system

通信设备制造车间

Telecom equipment manufacturing workshops

Antistatic epoxy self-leveling flooring for telecom base-station equipment workshops — protecting RF devices from ESD

航空航天电子车间

Aerospace electronics workshops

Antistatic flooring for aerospace electronics assembly — ESD protection for high-reliability electronics

汽车电子生产线

Automotive electronics production line

Antistatic epoxy flooring for new-energy vehicle electronic control production lines — dependable automotive electronics manufacturing

LED显示屏制造车间

LED display manufacturing workshop

Anti-static epoxy flooring for LED display packaging and testing workshops, electrostatic sensitive protection for optoelectronic semiconductors

化学品仓库防静电

Antistatic protection for chemical warehouses

Antistatic conductive epoxy flooring for flammable and explosive chemical warehouses — hazard storage safety and compliance

实验室防静电地坪

Laboratory antistatic flooring

Antistatic epoxy flooring for precision instrument analysis labs — protecting instruments from ESD interference

服务器托管机房

Colocation server rooms

Anti-static epoxy flooring for IDC server hosting data centers, ensuring safe operation of data center infrastructure

Technical documents MSDS (Material Safety Data Sheet) TDS Technical Data Sheet

Antistatic epoxy flooringFactory direct supply

Kexin antistatic epoxy flooring supplied directly from the source factory. Free sample testing, on-site engineer guidance, ISO-certified quality assurance.

Free sample testing
On-site engineer guidance
Fast dispatch within 48 hours
ISO-certified factory · direct supply

Related articles & news

Further reading: technical articles and industry news from Kexin New Materials