Cable fire protectioncoatings
KF-CF100 Cable Fire Retardant Coating
KF-CF100 Cable Fireproof Coating is based on waterborne acrylic emulsion and intumescent flame retardant system. Under flame or high temperature, the coating rapidly expands to form a dense char layer that insulates heat and oxygen, preventing flame spread along cables. Oxygen index greater than 45 / Flame retardant V0 grade / Low smoke and non-toxic. Widely used for fire protection coating of power/communication/control/ship cables.
ProductsOverview
Cable Fireproof Coating is a special fireproof coating developed by KeXin New Material. Designed according to GB 14907 and ISO 834 standards, the coating expands in fire to form a dense char layer, effectively blocking heat conduction, buying valuable time for personnel evacuation and fire rescue.
The product has passed national fire protection 3C certification and UL international certification, with fire resistance limit of 1-3 hours. Suitable for steel structures, concrete structures, cables and other buildings and industrial facilities requiring passive fire protection.
Why Choose Cable Fireproof Coating?
CoreAdvantages
Intumescent Flame Retardant · V0 Grade
The coating rapidly expands to 20-30 times its original thickness upon exposure to fire, forming a dense carbonized foam layer. The carbonized layer has a thermal conductivity of only 0.05W/mK, effectively blocking flame heat propagation. Oxygen index greater than 45, flame retardant UL94 V0 grade. According to GB/T18380 cable combustion test, flame does not spread.
Waterborne Eco-friendly · Low Smoke Non-toxic
Waterborne acrylic system, no solvent volatilization during application, VOC less than 50g per liter. The coating does not produce toxic smoke or corrosive gases in flames. Passed IMO FTP Code ship cable fire test and NES713 toxicity index test. Suitable for cable fire protection in enclosed spaces and densely populated areas.
Strong Adhesion · Good Flexibility
The coating has good adhesion to PVC/PE/XLPE/rubber and other cable sheath materials without peeling off. Good flexibility, does not crack when cable bends. Can be applied by brushing/dipping/spraying, adapting to cable bundles of different diameters and shapes. Single coat film thickness 0.5-1mm, multiple coats to achieve fire protection required film thickness.
Professional coating technology support services
Kexin has an experienced coating R&D and application team providing full-process support — from substrate analysis, coating selection and process-parameter optimization to on-site application guidance.
Eco-compliant green manufacturing system
All products are certified against the ROHS/REACH environmental regulations and their VOC content meets national environmental standards. Environmental performance test reports issued by authoritative third-party laboratories such as SGS and CTI are provided.
Complete quality control and batch traceability
A full-process quality control system, from incoming raw materials to dispatch of finished goods. Every batch passes rigorous physico-chemical testing and simulated coating trials. Each shipment is released with a batch test report and a product warranty.
TechnicalSpecifications
Basic parameters
Performance
The technical parameters above are taken from test data of the Kexin New Materials laboratory (ISO 17025 accredited); actual values may differ slightly depending on application conditions and substrate. Please contact technical support to obtain a current COA test report.
Frequently AskedFAQ
ApplicationProcess
Surface preparation
Clean substrates thoroughly of oil and rust. Blast steel to Sa2.5. Pre-treat per product spec to keep the substrate clean. Ambient 5-40°C, relative humidity<85%。
Primer / pre-treatment
Select the matching primer or pre-treatment per substrate and system. Mix strictly at the stated ratio and control DFT. Proceed after the primer dries; pre-stripe critical areas.
Main-coat application
Apply the main coat per the process spec, strictly controlling DFT, temperature/humidity and flash-off to keep the film uniform without sagging or pinholes.
Curing process
Cure fully by stoving or by ambient air drying as the product requires. Keep oven temperature uniform within ±5°C and ramp up gradually to avoid coating defects. For ambient-curing grades, ensure adequate ventilation and suitable humidity.
Inspection & acceptance
Inspect all parameters: dry film thickness, adhesion, gloss, colour difference and chemical resistance. Full performance testing is carried out against the relevant standards. Only after everything passes are the test report and warranty issued, and the goods are packed and shipped in dust-free conditions.
ApplicationsCases

Power Cable Fireproof Coating
Fire-resistant coatings applied to cables in substations and distribution rooms prevent flame propagation along the cables.

Control Cable Fireproof Coating
Industrial control system control cable fireproof coating for DCS and PLC safety

Communication Cable Fireproof Coating
Communication room and base station cable fireproof coating for data safety

Ship Cable Fireproof Coating
Fireproof coating for naval and merchant ship cables applied for offshore fire safety

Subway cable fireproof coating
Fireproof coating for subway station and tunnel cables applied for rail transit

Oil platform cable fireproof coating
Fireproof coating for offshore oil platform cables applied in explosive hazardous environments

Nuclear power plant cable fireproof coating
Fire-resistant coating for control and power cables in nuclear power plants, applied at the highest safety level

Data center cable fireproof coating
Fireproof coating for large data center cables applied for IT equipment power supply safety

High-rise building cable fireproof coating
Fireproof coating for super high-rise building shaft cables applied for fire escape routes

Coal mine cable fireproof coating
Fireproof coating for underground coal mine cables applied in gas environments

Chemical Plant Cable Fireproof Coating
Cable fireproof coating application for explosion-proof areas in chemical plants

Airport Cable Fireproof Coating
Cable fireproof coating application for airport terminals and runways
Related coatingsRecommended

Steel structure fire-retardant coating
Intumescent · 3h fire resistance · 3C certified
Learn more→
Outdoor thick-film fire protection of steel structures
Thick-film steel structure · Outdoor fireproofing · Durable
Learn more→
Tunnel fire-retardant coating
Tunnel-specific · HC standard · 2h fire resistance
Learn more→
Cable fire-retardant coating
Cable fireproofing · V0 grade · Flame retardant and arc resistant
Learn more→Cable Fireproof Coating·Factory direct supply
KeXin cable fireproof coating direct supply from source factory. Free sample testing, on-site guidance by technical engineers, ISO-certified quality assurance.
Related articles & news
Further reading: technical articles and industry news from Kexin New Materials