KF-CT100 Tank Lining Coating is a high-build epoxy coating designed specifically for the interior walls of chemical storage tanks. It offers outstanding chemical resistance — long-term resistance to 98% sulphuric acid, 37% hydrochloric acid, 50% sodium hydroxide, various solvents and oils. The dense, pinhole-free film (verified by high-voltage spark testing) prevents chemical penetration that would corrode the tank wall. Complies with GB 50393 Technical Code for Anti-Corrosion Engineering of Steel Petroleum Storage Tanks. A food-grade version (KF-FG500) is available for edible oil/drinking water tanks.
TDS Technical Data Sheet – Tank Lining Coating KF-CT100
Technical Data Sheet · Tank lining coating · KF-CT100
1. Product Description
2. Typical Applications
Inner walls of raw-material / finished-product storage tanks in chemical plants, inner walls of refinery oil tanks, linings of acid / alkali storage tanks, inner walls of wastewater treatment tanks / basins, and ship liquid-cargo holds. Different chemicals require different resin systems — please provide the stored medium and temperature conditions before selection.
3. Technical Parameters
| Product type | Two-component solvent-borne epoxy heavy-duty anti-corrosion coating |
|---|---|
| Color | Any colour to order |
| Gloss | Semi-gloss (30-60 GU) |
| Volume solids | 60±5% |
| Recommended DFT | 100-200 μm/coat |
| Theoretical spreading rate | 3.0-6.0 m²/L |
| Mixing ratio | A:B=4:1 (by weight) |
| Pot life | 4h(20°C) |
| Surface dry time (23°C) | ≤2h(23°C) |
| Hard dry time (23°C) | ≤24h(23°C) |
| Min. overcoat interval | 8h(23°C) |
| Full cure | 7 days (23°C) |
| Application temperature | 5-40°C |
| Relative humidity | <85% |
| Flash point (closed cup) | approx. 25°C |
| Density (mixed) | Approx. 1.6 kg/L |
| VOC content | <380 g/L |
| Adhesion | ≥5 MPa (pull-off test) |
| Packaging Specs | 20 L drum |
| Shelf Life | 12 months |
| Acid resistance | 10%H₂SO₄/30 days – no change |
| Alkali resistance | 10%NaOH/30 days – no change |
| Standard | ISO 12944-5 / HG/T 4564 |
4. Application Guide
Surface preparation
Thoroughly clean the substrate surface to remove oil and rust. Abrasive-blast steel to Sa2.5 (ISO 8501-1) with 40-75μm surface profile. Concrete substrate moisture content must be below 6%, grind to remove laitance. For old coatings, remove loose areas and roughen the surface.
Mixing / compounding
According to the mix ratio indicated on the product label, add the hardener (component B) slowly to the base (component A) and mechanically stir for 3-5 minutes until uniform. Let stand to mature for 10-15 minutes before use. Use up within the specified pot life after mixing.
Application method
Recommended air spray (gun orifice 1.5-2.0 mm, pressure 0.4-0.6 MPa) or airless spray (nozzle 0.38-0.53 mm, pressure 15-25 MPa). Small areas may be brushed or rolled. Keep each coat dry film thickness within the specified range.
Curing conditions
Self-cures at ambient temperature (23°C) provided relative humidity meets requirements. Do not apply under low temperature (<5°C) or high humidity (>85%). Conduct performance testing only after full cure.
5. Packaging & Storage
| Packaging Specs | 20 L drum |
|---|---|
| Storage Conditions | Store at 5–35°C in a cool, dry, ventilated place away from ignition and heat sources; keep container sealed. |
| Shelf Life | 12 months |
| Transport | Transport as non-hazardous goods. In summer, ship in early morning or evening; avoid sun exposure. |
6. Health & Safety Notes
⚠️ Important safety notice
Read and understand the product's MSDS (Material Safety Data Sheet) carefully before using this product.
- Proper personal protective equipment (gloves, goggles, protective suit) must be worn during application
- Ensure the work area is well ventilated
- Keep away from fire and heat sources
- Avoid inhaling vapours and mist
- Avoid contact with skin and eyes
- If you feel unwell, stop work immediately and seek medical advice
Disclaimer
The data in this TDS are typical values and do not constitute product specifications. Actual product performance may vary depending on application conditions, substrate condition and environmental factors. Users are advised to conduct small-scale sample tests before bulk use to confirm product suitability.
Kexin New Materials continuously improves its products and reserves the right to modify product technical parameters without prior notice. For the latest version, please visit www.psste.com/chemical-tank-lining-coating-tds/ page.⬇ Download this document (PDF)
Related articles & news