1 Identification of the substance / mixture and of the company / undertaking

Product NamePC scratch-resistant hardened coating KF-PC300
Recommended usePC scratch-resistant hard coating is suitable for industrial coating applications related to UV-curable coatings.
Use restrictionsIntended only for industrial coatings applied on a UV-curing production line. UV light is harmful to persons; operators must be protected against UV radiation.
ManufacturerKexin New Materials (Guangdong) Co., Ltd.
ProducerFoshan Shunde Mingbang Chemical Industry Co., Ltd.
AddressNo. 19 Shilong Avenue, Xintang Industrial Zone, Lunjiao, Shunde, Foshan, Guangdong
Emergency telephone+86-0757-88793275
Websitehttps://www.psste.com

2 Hazard identification

Signal word: Warning
❗GHS07

Hazard Statements

  • Skin Irrit. 2: H315
  • Eye Irrit. 2: H319
  • Skin Sens. 1: H317 (UV monomer)
  • Aquatic Chronic 3: H412

Precautionary Statements

  • P280: Wear protective gloves / goggles / protective clothing. For UV work, additionally: UV face shield.
  • P302+P352: Skin contact: wash with soap and water.
  • P305+P351+P338: Eye contact: rinse for 15 minutes.

3 Composition / information on ingredients

Chemical substanceCAS No.Concentration rangeGHS classification
Urethane acrylate / epoxy acrylate / polyester acrylate oligomers.Mixture (UV-curable resin)40-70%Not hazardous (high-molecular-weight oligomer)
Reactive diluent/monomer (multifunctional acrylates such as HDDA/TPGDA/TMPTA).13048-33-4 (HDDA); 15625-89-5 (TMPTA), etc.20-40%Skin Irrit. 2 (H315), Eye Irrit. 2 (H319), Skin Sens. 1 (H317)
Photoinitiator blendMultiple variations2-5%Skin Sens. (partial)

4 First-aid measures

Inhalation

Move to fresh air.

Skin contact

Wash immediately with soap and water. Acrylate monomers may cause skin sensitization.

Eye contact

Rinse for 15 minutes. Seek medical attention.

Ingestion

Rinse mouth. Seek medical advice.

Most important symptoms and effects:Skin irritation / sensitization (delayed contact dermatitis).

Conditions requiring immediate medical attention:Symptomatic treatment. Those sensitised should avoid further exposure.

5 Fire-fighting measures

Suitable extinguishing mediaDry powder / CO2 / foam. UV coatings are usually solvent-free or low-solvent and are not readily flammable.
Unsuitable extinguishing media
Specific hazards
Special protective equipment for firefighters

6 Spill release measures

Operator protection:

Environmental precautions:

Containment and cleaning methods:

7 Handling and storage

Precautions for safe handling

Handle away from UV/daylight. Take measures against UV radiation: shield the work area from UV light. Avoid skin contact with uncured coating (acrylate sensitization). No eating or drinking in the workplace.

Storage Conditions

Store protected from light (to prevent unintended polymerization). <30°C. Shelf life 6-12 months. Periodically check for any rise in viscosity (a sign of polymerization).

8 Exposure controls / personal protection

substancePC-TWAPC-STELStandard

Engineering controls

Personal Protective Equipment (PPE)

Respiratory systemUsually not required (solvent-free) — wear P2 when spraying UV coatings
Hand protectionNitrile gloves (multilayer + frequent change, as monomers can permeate the glove).
Eye protectionUV protection face shield + safety goggles
Skin and bodyLong-sleeved protective suit. Cover all skin (dual protection against UV light and monomer).

9 Physical and chemical properties

AppearanceClear to slightly yellow liquid, or any colour
Flash Point>100°C (most UV coatings are solvent-free)
Relative Density1.0-1.2
ViscosityWide range: 50-5,000 mPa·s (product dependent)
Solids content>95% (solvent-free type)
VOC content<5% (very low or no VOC)

10 Stability and reactivity

ReactivityUV/visible-light initiated polymerization——store protected from light!
Chemical stability
Possibility of hazardous reactions
Conditions to avoidUVlight, sunlight, high temperature.
Incompatible materialsStrong oxidizers.
Hazardous decomposition products

11 Toxicological information

Other toxicological information

12 Ecological information

Persistence and degradability

Bioaccumulative potential

Mobility in soil

Other adverse effects

13 Disposal

Disposal method:Liquid UV waste: HW12. It is recommended to UV-cure it first (once cured it becomes an inert solid, i.e. general industrial solid waste) before disposal.

Contaminated packaging disposal:

14 Transport Info

UN No.Not restricted (solvent-free, flash point >93°C)
Proper shipping nameNot regulated
Transport hazard class
Packing group
Environmental Hazards
Special precautions

15 Regulatory Info

Chinese regulations

    International regulations

      16 Other information

      Revision date:2026-06-08

      Version:1.0

      References

      • ECHA Registered Substances Database (echa.europa.eu)
      • NIOSH Pocket Guide to Chemical Hazards (cdc.gov/niosh/npg)
      • PubChem Compound Database (pubchem.ncbi.nlm.nih.gov)
      • GBZ 2.1-2019 Occupational exposure limits for hazardous agents in the workplace — Chemical hazardous agents
      • GBZ/T 195-2007 Occupational health management specification for workplaces using organic solvents
      • IARC Monographs on the Evaluation of Carcinogenic Risks to Humans

      Abbreviations

      GHS: Globally Harmonized System of Classification and Labelling of Chemicals; PC-TWA: Permissible Concentration-Time Weighted Average; PC-STEL: Short Term Exposure Limit; OEL: Occupational Exposure Limit; PPE: Personal Protective Equipment; LD₅₀: Lethal Dose 50%; LC₅₀: Lethal Concentration 50%; EC₅₀: Effect Concentration 50%; BCF: Bioconcentration Factor; Kow: Octanol-Water Partition Coefficient; SCBA: Self-Contained Breathing Apparatus; PBT: Persistent, Bioaccumulative and Toxic; vPvB: very Persistent and very Bioaccumulative; COA: Certificate of Analysis

      Disclaimer:This MSDS was compiled from public chemical databases such as ECHA, NIOSH and PubChem together with typical industry formulations, and is for reference only. CAS numbers have been verified against public databases. The exact proportion of each component is a core technology secret of the plant, so this document states typical industry concentration ranges. Actual data shall be taken from the plant batch test report and the Certificate of Analysis (COA). Kexin New Materials assumes no legal liability arising from use of the information in this MSDS. Users shall assess the suitability and safety of the product under their own specific conditions of use and comply with all applicable local laws and regulations. This document was compiled in accordance with GB/T 16483-2008 and comprises 16 sections.