隧道防火涂料
KF-TF100 Tunnel Fireproof Coating
KF-TF100隧道防火涂料以水泥和膨胀蛭石/珍珠岩为基料添加防火纤维和外加剂。涂层厚度15-25mm喷涂在隧道混凝土衬砌表面。按隧道HC升温曲线测试耐火极限大于2小时。A1级不燃材料。广泛用于公路/铁路/地铁/城市隧道和地下综合管廊的被动防火保护。
产品概述
隧道防火涂料是客信新材料研发的特种防火涂料。按 GB 14907 和 ISO 834 标准设计,涂层在火灾中膨胀形成致密炭化层,有效阻隔热传导,为人员疏散和消防救援争取宝贵时间。
产品通过国家消防 3C 认证和 UL 国际认证,耐火极限 1-3 小时。适用于钢结构、混凝土结构、电缆等需要被动防火保护的建筑和工业设施。
为什么选择隧道防火涂料?
核心优势
HC隧道火曲线·2小时耐火
按RABT-ZTV隧道火灾升温曲线(120分钟达1200度)测试。25mm厚涂层耐火极限大于2小时。在隧道火灾(油罐车/货车燃烧)极端场景下保护混凝土衬砌不爆裂不坍塌保障人员逃生和救援通道安全。
水泥基不燃·耐久环保
水泥和膨胀矿物骨料体系A1级不燃材料。高温不产生有毒烟气和熔融滴落物。涂层耐潮湿/耐CO2碳化/耐隧道内车辆尾气侵蚀。设计使用寿命大于30年与隧道结构同寿。
机械喷涂·施工高效
专用螺杆泵湿喷机机械喷涂每台班可喷涂500-800平方米。与隧道防水层和二次衬砌施工工序衔接合理。可在隧道贯通后分段喷涂工期可控。涂层与混凝土粘接力大于0.3MPa。
Professional coating technology support services
Kexin boasts an experienced coatings R&D and application technology team that provides a full range of services, from substrate analysis and coating selection to process parameter optimization and on-site construction guidance.
Environmentally compliant green manufacturing system
All products are RoHS/REACH certified and their VOC content meets national environmental standards. Environmental performance test reports from authoritative third-party testing organizations such as SGS and CTI are provided.
Comprehensive quality control and batch traceability
A comprehensive quality control system is in place from raw material intake to finished product delivery. Each batch of products undergoes rigorous physical and chemical performance testing and coating simulation testing. A batch test report and product quality certificate are included with each shipment.
技术规格
Basic parameters
Performance indicators
The above technical parameters are from the testing data of Kexin New Materials Laboratory (ISO 17025 certified). Actual values may vary slightly due to construction environment and substrate conditions. For the latest technical data, please contact technical support to obtain the COA test report.
常见问题
施工流程
Surface treatment
Thoroughly clean the substrate to remove oil and rust. Sandblast steel to Sa2.5 grade. Perform surface pretreatment according to product requirements to ensure substrate cleanliness. Ambient temperature 5-40°C, relative humidity...<85%。
Primer/Pretreatment
Select a suitable primer or pretreatment based on the substrate and product system. Strictly control film thickness by mixing according to the product ratio. Proceed to the next process after the primer has dried. Apply a reinforcing pre-coat to critical areas.
Main coating application
Apply the main coating according to the process requirements. Strictly control application parameters such as film thickness, ambient temperature and humidity, and flash-off time. Ensure a uniform coating free of runs and pinholes.
Curing process
Bake or air dry at room temperature until fully cured according to product requirements. Maintain a uniform oven temperature (±5°C) and gradually increase the temperature to avoid coating defects. For room temperature curing, ensure adequate ventilation and suitable humidity.
Inspection and Acceptance
We test all indicators including film thickness, adhesion, gloss, color difference, and chemical resistance. We conduct comprehensive performance testing according to relevant standards. After all tests pass, we issue a test report and quality assurance certificate, and ship the product in dust-free packaging.
应用案例

公路隧道防火涂料
公路隧道混凝土衬砌防火涂料喷涂HC防火标准2小时耐火

铁路隧道防火涂料
铁路隧道防火涂料喷涂列车火灾场景防护

地铁隧道防火涂料
地铁区间隧道防火涂料喷涂区间段被动防火

城市隧道防火涂料
城市下穿隧道防火涂料喷涂交通枢纽防火

水下隧道防火涂料
江底和海底沉管隧道防火涂料喷涂水下隧道

山岭隧道防火涂料
山岭钻爆隧道防火涂料喷涂初支和二衬防火

电力隧道防火涂料
电力电缆隧道防火涂料喷涂电缆火灾防护

综合管廊防火涂料
城市地下综合管廊防火涂料喷涂多舱防火

隧道联络通道防火涂料
隧道联络通道和逃生通道防火涂料喷涂

矿山巷道防火涂料
煤矿和金属矿山巷道防火涂料喷涂

隧道洞门防火涂料
隧道洞门和遮光棚防火涂料喷涂

隧道运营维护防火涂料
运营隧道防火涂料修补和加固喷涂维护
Related coatingsProduct Recommendations
隧道防火涂料·Direct from the source factory
客信隧道防火涂料源头工厂直供。免费样品测试,技术工程师驻场指导,ISO认证品质保障。