| Product Name | Waterborne Fluorocarbon Coating KF-WF100 |
|---|---|
| Recommended use | Waterborne fluorocarbon coating is intended for industrial coating applications in the fluorocarbon coating category. |
| Use restrictions | For industrial coating use only. FEVE fluorocarbon paint must be used together with an isocyanate hardener — see the isocyanate safety precautions in the PU-series MSDS. |
| Manufacturer | Kexin New Materials (Guangdong) Co., Ltd. |
| Producer | Foshan Shunde Mingbang Chemical Industry Co., Ltd. |
| Address | No. 19 Shilong Avenue, Xintang Industrial Zone, Lunjiao, Shunde, Foshan, Guangdong |
| Emergency telephone | +86-0757-88793275 |
| Website | https://www.psste.com |
MSDS (Material Safety Data Sheet) – Waterborne Fluorocarbon Coating KF-WF100
Material Safety Data Sheet · GB/T 16483-2008 · 16 chapters
1 Identification of the substance / mixture and of the company / undertaking
2 Hazard identification
Hazard Statements
- Flam. Liq. 3: H226
- Acute Tox. 4 (Inhalation): H332
- Skin Irrit. 2: H315
- Eye Irrit. 2: H319
- Resp. Sens. 1: H334 (isocyanate-containing products)
- Skin Sens. 1: H317
- STOT SE 3: H336
Precautionary Statements
- 0: P210
- 1: P261
- 2: P280
- 3: P284
- 4: P302+P352
- 5: P304+P340
- 6: P342+P311
- 7: P403+P235
3 Composition / information on ingredients
| Chemical substance | CAS number | Concentration range | GHS classification |
|---|---|---|---|
| FEVE fluororesin (Fluoroethylene-Vinyl Ether copolymer, OH-functional) | No single CAS (fluoropolymer) | 25-40% | Non-hazardous substance (polymer) |
| HDI trimer hardener | 28182-81-2 | Component B:70-90% | Resp. Sens. 1 (H334), Skin Sens. 1 (H317) |
| Butyl acetate / xylene | 123-86-4 / 1330-20-7 | 20-40% | Flam. Liq. 3, STOT SE 3 |
4 First-aid measures
Inhalation
Move to fresh air. Isocyanates may cause delayed-onset asthma. Seek medical attention.
Skin contact
Wash with soap and water. PEG 400 enhances removal of isocyanates.
Eye contact
Rinse for 15 minutes. Seek medical attention.
Ingestion
Do not induce vomiting. Seek medical attention.
Most important symptoms and effects:As with PU systems: isocyanate sensitisation/asthma, solvent-induced dizziness.
Conditions requiring immediate medical attention:Persons sensitized to isocyanates must permanently avoid exposure.
5 Fire-fighting measures
| Suitable extinguishing media | Dry powder / CO₂ / foam / water mist |
|---|---|
| Inappropriate Extinguishing Media | |
| Specific hazards | Combustion: CO, NOx, HF (trace hydrogen fluoride when fluororesin burns) |
| Special protective equipment for firefighters | SCBA + chemical protective suit |
6 Spill release measures
Operator protection:Full PPE + supplied-air respirator
Environmental precautions:Prevent entry into water bodies. Fluoropolymers are environmentally persistent.
Containment and cleaning methods:Absorb with absorbent material. Decontaminate residual isocyanate in liquefied form.
7 Handling and storage
Precautions for safe handling
Spray booth application. Isocyanate safety training.
Storage Conditions
5-30°C. Keep hardener dry. Store separately.
8 Exposure controls / personal protection
| substance | PC-TWA | PC-STEL | Standard |
|---|---|---|---|
| HDI monomer | 0.005 ppm | 0.01 ppm | GBZ 2.1-2019 |
| Butyl acetate | 200 mg/m³ | 300 mg/m³ | GBZ 2.1-2019 |
Engineering controls
Spray booth. Isocyanate monitoring.
Personal Protective Equipment (PPE)
| Respiratory system | Supplied-air respirator (SAR) |
|---|---|
| Hand protection | Nitrile rubber |
| Eye protection | Full-face respirator |
| Skin and body | Full body protection |
9 Physical and chemical properties
| Appearance | Liquid in various colours (gloss/matt) |
|---|---|
| Flash Point | 23-28°C |
| Relative Density | 1.0-1.4 |
| Solubility | Insoluble in water |
| VOC content | <420 g/L(solvent)/<150(Water-Based) |
10 Stability and reactivity
| Reactivity | Isocyanates react with water. |
|---|---|
| Chemical stability | |
| Possibility of hazardous reactions | |
| Conditions to avoid | High temperature and humidity |
| Incompatible materials | Water, alcohols, amines |
| Hazardous decomposition products |
11 Toxicological information
Other toxicological information
| May cause allergy from inhalation or skin contact | Isocyanates: H334+H317. Note: the fluororesin itself is not a sensitiser — the hazard comes from the hardener. |
|---|
12 Ecological information
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Other adverse effects
13 Disposal
Disposal method:HW12+HW06. Fluorine-containing waste requires high-temperature incineration (>1,200°C) to ensure complete decomposition of fluoropolymers.
Contaminated packaging disposal:
14 Transport Info
| UNNumber | UN1263 |
|---|---|
| Proper shipping name | Paint |
| Transport hazard class | Class 3 |
| Packing group | PG III |
| Environmental Hazards | |
| Special precautions |
15 Regulatory Info
Chinese regulations
- GB/T 16483-2008
- GB 30981-2020
- AAMA 2605(Fluorocarbon coating performance standard)
International regulations
- EU REACH
- PFAS regulations (fluoropolymers are under global evaluation — monitor regulatory developments)
16 Other information
Revision date:2026-06-08
Version:1.0
References
- ECHA Registered Substances Database (echa.europa.eu)
- NIOSH Pocket Guide to Chemical Hazards (cdc.gov/niosh/npg)
- PubChem Compound Database (pubchem.ncbi.nlm.nih.gov)
- GBZ 2.1-2019 Occupational exposure limits for hazardous agents in the workplace — Chemical hazardous agents
- GBZ/T 195-2007 Occupational health management specification for workplaces using organic solvents
- IARC Monographs on the Evaluation of Carcinogenic Risks to Humans
Abbreviations
GHS: Globally Harmonized System of Classification and Labelling of Chemicals; PC-TWA: Permissible Concentration-Time Weighted Average; PC-STEL: Short Term Exposure Limit; OEL: Occupational Exposure Limit; PPE: Personal Protective Equipment; LD₅₀: Lethal Dose 50%; LC₅₀: Lethal Concentration 50%; EC₅₀: Effect Concentration 50%; BCF: Bioconcentration Factor; Kow: Octanol-Water Partition Coefficient; SCBA: Self-Contained Breathing Apparatus; PBT: Persistent, Bioaccumulative and Toxic; vPvB: very Persistent and very Bioaccumulative; COA: Certificate of Analysis
⬇ Download this document (PDF)