Home / Products / Industrial Coatings / Outdoor thick-film intumescent fireproof coating for steel structures
3-hour fire resistance · steel structure protection

Outdoor thick-film fire protection of steel structurescoatings

KF-HF100 Thick-Film Fireproof Coating

KF-HF100 outdoor thick-film steel structure fireproof coating is based on cement and expanded vermiculite perlite with added fireproof fibers. The coating thickness is 20-40mm and is sprayed onto the steel structure surface. Tested according to the ISO 834 standard heating curve, the fire resistance limit is greater than 3 hours. As an A1-class non-combustible material, it is weather-resistant and suitable for outdoor steel structures. It is widely used for passive fire protection of sports venues, airports, exhibition centers, high-rise buildings, and petrochemical steel structures.

9Major Series
All-substrate coverage
95GU+
high-gloss baked finish
5MPa+
adhesion strength
500h+
Salt spray resistance
200°C
Baking temperature
ROHSCertifications
Eco compliance
ΔE<1
precise colour control
12 months
Shelf Life
SourceFactory
Factory-direct quality

ProductsOverview

Outdoor thick-film steel structure fireproof coating is a special fireproof coating developed by KeXin New Material. Designed according to GB 14907 and ISO 834 standards, the coating expands in a fire to form a dense carbonized layer, effectively blocking heat conduction and buying valuable time for personnel evacuation and fire rescue.

The product has passed national fire protection 3C certification and UL international certification, with fire resistance limit of 1-3 hours. Suitable for steel structures, concrete structures, cables and other buildings and industrial facilities requiring passive fire protection.

Why choose outdoor thick-film steel structure fireproof coating?

✓
ISO-certified factory · direct from the manufacturer——End-to-end quality control from raw material to finished product, no trader margin
✓
Free sample testing · quality you can see——Samples from 1 kg, supplied with TDS and MSDS documentation
✓
On-site engineer guidance——Free on-site service in the Pearl River Delta region, remote technical support elsewhere
✓
Fast dispatch within 48 hours——Standard products well stocked; custom orders in 3-7 working days
✓
Complete coating system solutions——Primer / midcoat / topcoat systems designed as a matched set, one-stop procurement
✓
RoHS / REACH environmental compliance——Tested by third-party laboratories SGS/CTI, exported to 50+ countries

CoreAdvantages

3-hour fire resistance · ISO 834

The 40mm thick coating has a fire resistance limit greater than 3 hours according to the ISO 834 standard fire heating curve. Under a 1000-degree flame, the steel structure surface temperature is kept within 538 degrees (the critical failure temperature of steel) for 3 hours. This wins valuable time for personnel evacuation and fire rescue.

Outdoor durability · A1 non-combustible

The cement and mineral material system is A1-class non-combustible. It resists rain, freezing, ultraviolet radiation, and other outdoor climatic conditions without chalking or peeling for a long time. Its adhesion with steel structure anti-rust primer is greater than 0.1MPa. The outdoor service life is greater than 20 years.

Hydrocarbon fire · dedicated for petrochemicals

The formula is optimized for hydrocarbon fires in petrochemicals and other industries (faster heating and higher temperatures). Tested according to the UL 1709 hydrocarbon fire heating curve, the fire resistance limit is greater than 2 hours. It meets the special fire protection needs of petrochemical plants, offshore platforms, liquefied natural gas facilities, and more.

Professional coating technology support services

Kexin has an experienced coating R&D and application team providing full-process support — from substrate analysis, coating selection and process-parameter optimization to on-site application guidance.

Eco-compliant green manufacturing system

All products are certified against the ROHS/REACH environmental regulations and their VOC content meets national environmental standards. Environmental performance test reports issued by authoritative third-party laboratories such as SGS and CTI are provided.

Complete quality control and batch traceability

A full-process quality control system, from incoming raw materials to dispatch of finished goods. Every batch passes rigorous physico-chemical testing and simulated coating trials. Each shipment is released with a batch test report and a product warranty.

TechnicalSpecifications

Basic parameters

Suitable substratesCovers all common substrate types
Coating typesAcrylic / PU / epoxy / UV
Curing methodBaking / air drying / UV curing
Gloss rangeHigh gloss / semi-gloss / matt
Colour optionsPrecise matching in any colour
Industries servedUsed across many industries
Environmental certificationROHS/REACH/GB
Packaging Specs4 L / 20 L drum packaging

Performance

Adhesion (cross-cut)Grade 0–1 (5B)
Pencil hardnessH-2H
Salt spray resistance240-500h
Damp-heat resistanceNo abnormality after 500 h
Perspiration resistantNo abnormality after 48 h
RCA abrasion resistance>200 cycles
Impact resistance50kg·cm
VOC content<420g/L

The technical parameters above are taken from test data of the Kexin New Materials laboratory (ISO 17025 accredited); actual values may differ slightly depending on application conditions and substrate. Please contact technical support to obtain a current COA test report.

Frequently AskedFAQ

Which substrates and scenarios does it suit?+
Suitable for many common substrates, including steel, concrete, wood and plastics. Widely used in industrial manufacturing, architectural decoration, automotive and transport, furniture and home furnishings. For professional selection advice, call 400-901-0757.
What is the application method?+
Apply by conventional spray, brush or roller. Substrate must be clean, dry and grease-free. Ambient temperature 5-35°C, relative humidity <85% 为BestApplicationConditions。SpecificParameters — see Products TDS Technical Data Sheet。
Which primer or topcoat completes the system?+
We recommend using a matching primer and topcoat from the same Kexin series to secure system compatibility and best performance. A Kexin engineer can design a complete primer-midcoat-topcoat system for your specific service conditions, free of charge.
How to get samples and a quote?+
Free samples of standard products are provided (freight at the customer's cost), supplied with TDS and MSDS documentation. For bulk purchases please contact 400-901-0757 or 13531350189. Sample quantity from 1 kg; bulk orders from 20 kg.
How do I pick the right grade for my operating conditions?+
Choosing a coating product requires considering the substrate type, the service environment (temperature / humidity / chemical media), the required corrosion protection class (ISO 12944 C1-C5M), the application conditions and the budget. We recommend contacting our technical engineer on 400-901-0757 for professional selection advice; free trial spraying and test verification are supported.
What is the MOQ and lead time?+
Samples from 1 kg; regular products from 20 kg per batch. Stock items ship within 48 hours, made-to-order products in 3-7 working days. Door delivery can be arranged within the Pearl River Delta region.

ApplicationProcess

1

Surface preparation

Clean substrates thoroughly of oil and rust. Blast steel to Sa2.5. Pre-treat per product spec to keep the substrate clean. Ambient 5-40°C, relative humidity<85%。

2

Primer / pre-treatment

Select the matching primer or pre-treatment per substrate and system. Mix strictly at the stated ratio and control DFT. Proceed after the primer dries; pre-stripe critical areas.

3

Main-coat application

Apply the main coat per the process spec, strictly controlling DFT, temperature/humidity and flash-off to keep the film uniform without sagging or pinholes.

4

Curing process

Cure fully by stoving or by ambient air drying as the product requires. Keep oven temperature uniform within ±5°C and ramp up gradually to avoid coating defects. For ambient-curing grades, ensure adequate ventilation and suitable humidity.

5

Inspection & acceptance

Inspect all parameters: dry film thickness, adhesion, gloss, colour difference and chemical resistance. Full performance testing is carried out against the relevant standards. Only after everything passes are the test report and warranty issued, and the goods are packed and shipped in dust-free conditions.

ApplicationsCases

体育场馆钢结构防火

Fire protection for steel structures in sports venues

Thick-film fireproof coating sprayed on steel structures of large sports venues for 3-hour fire resistance

机场航站楼钢结构防火

Fire protection for steel structures in airport terminals

Thick fireproof paint spraying for large-span steel structures in airport terminals, fire protection

会展中心钢结构防火

Fire protection for steel structures of exhibition centers

Thick-film fireproof coating spraying for steel structures of exhibition halls in exhibition centers

高层建筑钢结构防火

Fire protection for steel structures of high-rise buildings

Thick fireproof coatings for steel structures of super high-rise buildings are sprayed on columns and beams for fire protection.

工业厂房钢结构防火

Fire protection for steel structures of industrial plants

Thick-film fireproof coating spraying for steel structures of heavy industrial plants in outdoor environments

石化装置钢结构防火

Fire protection for steel structures of petrochemical facilities

Thick fireproof paint spraying for steel structures in petrochemical plants, hydrocarbon fire protection

桥梁钢结构防火

Fire protection for steel structures of bridges

Thick-film fireproof coating spraying for steel structures of long-span bridges

火车站钢结构防火

Fire protection for steel structures of railway stations

Thick-film fireproof coating for steel structures of high-speed railway station buildings

仓储钢结构防火

Fire protection for steel structures of warehouses

Thick-film fireproof coating spraying for steel structures of large logistics warehouses

电厂钢结构防火

Power Plant Steel Structure Fire Protection

Thick-Film Fireproof Coating for Main Powerhouse Steel Structures in Thermal Power Plants

海洋平台钢结构防火

Offshore Platform Steel Structure Fire Protection

Thick fireproof paint spraying for offshore platform steel structures, hydrocarbon fire protection

钢结构管廊防火

Steel Structure Pipe Rack Fire Protection

Thick-Film Fireproof Coating for Industrial Pipe Rack and Cable Tray Steel Structures

Technical documents MSDS (Material Safety Data Sheet) TDS Technical Data Sheet

Outdoor Thick-Film Steel Structure Fireproof Coating·Factory direct supply

KeXin Outdoor Thick-Film Steel Structure Fireproof Coating, direct supply from source factory. Free sample testing, on-site guidance by technical engineers, ISO-certified quality assurance.

Free sample testing
On-site engineer guidance
Fast dispatch within 48 hours
ISO-certified factory · direct supply

Related articles & news

Further reading: technical articles and industry news from Kexin New Materials