KF-GF100 epoxy glass-flake coating replaces MIO as the main anti-corrosive pigment with micron-scale glass flakes (Glass Flake, thickness about 5 micrometers, particle size 50-500 micrometers). The glass flakes form a barrier of dozens of overlapping layers within the coating, giving permeation resistance 10-50 times higher than conventional epoxy coatings. A dry film thickness of 200-500 micrometers can be achieved in a single application without sagging. It is especially suitable for immersion service (tank interiors, sewage pools, ship hulls below the waterline) and severe chemical-corrosion environments. Excellent resistance to seawater, acids, alkalis and salt solutions.
TDS Technical Data Sheet – Epoxy Glass Flake Coating KF-GF100
Technical Data Sheet · Epoxy Glass-flake Coating · KF-GF100
1. Product Description
2. Typical Applications
Lining of chemical storage tanks and reactor interiors; interiors of sewage-treatment and neutralization pools; seawater cooling systems and piping; ship hulls below the waterline and ballast tanks (IMO PSPC approved); offshore platform splash zones (the most severe corrosion area); internal corrosion protection of desulfurization towers (FGD).
3. Technical Parameters
| Product type | Two-component solvent-borne epoxy intermediate coat |
|---|---|
| Color | Iron-red / gray |
| Gloss | Matt (<20 GU) |
| Volume solids | 55±3% |
| Recommended DFT | 80-150 μm/coat |
| Theoretical spreading rate | 3.7-6.9 m²/L |
| Mixing ratio | A:B = 5:1 (by weight) |
| Pot life | 6h(20°C) |
| Surface dry time (23°C) | ≤2h(23°C) |
| Hard dry time (23°C) | ≤24h(23°C) |
| Min. overcoat interval | 6 h (23°C); up to 7 days at most |
| Full cure | 7 days (23°C) |
| Application temperature | 5-40°C |
| Relative humidity | <85% |
| Flash point (closed cup) | Approx. 28°C |
| Density (mixed) | Approx. 1.8 kg/L |
| VOC content | <400 g/L |
| Adhesion | Grade 0–1 |
| Packaging Specs | 20 L drum |
| Shelf Life | 12 months |
| Salt spray resistance | ≥300 h (with primer) |
| Water vapour transmission rate | ≤50 g/m²·d |
| Standard | ISO 12944-5 / GB/T 25263 |
| Product type | Two-component epoxy glass-flake heavy-duty anti-corrosion coating |
| Recommended DFT | 200-500 μm/coat (high-build type) |
| Color | Grey / Grey-green / White |
4. Application Guide
Surface preparation
Thoroughly clean the substrate surface to remove oil and rust. Abrasive-blast steel to Sa2.5 (ISO 8501-1) with 40-75μm surface profile. Concrete substrate moisture content must be below 6%, grind to remove laitance. For old coatings, remove loose areas and roughen the surface.
Mixing / compounding
According to the mix ratio indicated on the product label, add the hardener (component B) slowly to the base (component A) and mechanically stir for 3-5 minutes until uniform. Let stand to mature for 10-15 minutes before use. Use up within the specified pot life after mixing.
Application method
Recommended air spray (gun orifice 1.5-2.0 mm, pressure 0.4-0.6 MPa) or airless spray (nozzle 0.38-0.53 mm, pressure 15-25 MPa). Small areas may be brushed or rolled. Keep each coat dry film thickness within the specified range.
Curing conditions
Self-cures at ambient temperature (23°C) provided relative humidity meets requirements. Do not apply under low temperature (<5°C) or high humidity (>85%). Conduct performance testing only after full cure.
5. Packaging & Storage
| Packaging Specs | 20 L drum |
|---|---|
| Storage Conditions | Store at 5–35°C in a cool, dry, ventilated place away from ignition and heat sources; keep container sealed. |
| Shelf Life | 12 months |
| Transport | Transport as non-hazardous goods. In summer, ship in early morning or evening; avoid sun exposure. |
6. Health & Safety Notes
⚠️ Important safety notice
Read and understand the product's MSDS (Material Safety Data Sheet) carefully before using this product.
- Proper personal protective equipment (gloves, goggles, protective suit) must be worn during application
- Ensure the work area is well ventilated
- Keep away from fire and heat sources
- Avoid inhaling vapours and mist
- Avoid contact with skin and eyes
- If you feel unwell, stop work immediately and seek medical advice
Disclaimer
The data in this TDS are typical values and do not constitute product specifications. Actual product performance may vary depending on application conditions, substrate condition and environmental factors. Users are advised to conduct small-scale sample tests before bulk use to confirm product suitability.
Kexin New Materials continuously improves its products and reserves the right to modify product technical parameters without prior notice. For the latest version, please visit www.psste.com/epoxy-glass-flake-coating-tds/ page.⬇ Download this document (PDF)