KF-GF100 Epoxy Glass Flake Coating

KF-GF100 epoxy glass flake coating uses epoxy resin as the base material with 10-30% micron-sized glass flakes added. The flakes are arranged in parallel overlapping layers within the coating to form a labyrinth effect, reducing water vapor transmission rate to 1/10 of ordinary epoxy and chloride ion penetration depth to less than 0.5mm. It provides ultimate barrier protection, chemical resistance, wear resistance, and impact resistance. Widely used for heavy-duty anti-corrosion coating of steel structures in extreme corrosive environments such as offshore platforms/ships/storage tanks/FGD desulfurization.

9Major Series
All-substrate coverage
95GU+
high-gloss baked finish
5MPa+
adhesion strength
500h+
Salt spray resistance
200°C
Baking temperature
ROHSCertifications
Eco compliance
ΔE<1
precise colour control
12 months
Shelf Life
SourceFactory
Factory-direct quality

ProductsOverview

Epoxy glass flake coating is a high-performance professional coating product developed and produced by KeXin New Material. It is scientifically formulated with high-quality resins and imported pigments and fillers, featuring excellent adhesion, durability, and application performance. Widely used in industrial manufacturing, architectural decoration, automotive transportation, and other fields.

As a source coating factory, KeXin New Material strictly implements the ISO9001 quality management system for epoxy glass flake coating from formula design and raw material procurement to production and filling. The product has passed ROHS, REACH, and other environmental regulation certifications. Free sample testing and on-site guidance by technical engineers are provided.

Why choose epoxy glass-flake coating?

✓
ISO-certified factory · direct from the manufacturer——End-to-end quality control from raw material to finished product, no trader margin
✓
Free sample testing · quality you can see——Samples from 1 kg, supplied with TDS and MSDS documentation
✓
On-site engineer guidance——Free on-site service in the Pearl River Delta region, remote technical support elsewhere
✓
Fast dispatch within 48 hours——Standard products well stocked; custom orders in 3-7 working days
✓
Complete coating system solutions——Primer / midcoat / topcoat systems designed as a matched set, one-stop procurement
✓
RoHS / REACH environmental compliance——Tested by third-party laboratories SGS/CTI, exported to 50+ countries

CoreAdvantages

Labyrinth Effect · Ultimate Barrier

Micron-scale glass flakes (thickness 2-5 microns / particle size 50-200 microns) are arranged in parallel overlapping layers within the coating. Water molecules and corrosive ions must bypass layer upon layer of flakes to reach the substrate, extending the permeation path by 50-100 times. Chloride ion penetration depth is less than 0.5mm (EN13396), approximately 1/20 that of ordinary epoxy.

Chemical Resistance · Storage Tank Lining

Resistant to 98% sulfuric acid / 37% hydrochloric acid / 85% phosphoric acid / sodium hydroxide / seawater / crude oil / refined oil, etc. Widely used in chemical storage tanks / waste liquid pools / reactors / desulfurization absorption towers and other extreme working conditions requiring simultaneous chemical resistance and wear resistance. Coating thickness of 500-1000 microns can be achieved in a single application.

Wear Resistance · Impact Resistance

Glass flakes significantly enhance coating hardness and wear resistance. Taber abrasion less than 30mg (C-17 wheel 1000g 1000 cycles). Resistant to slurry and solids-containing fluid erosion, resistant to gravel and hail impact. It is the preferred coating solution for heavy-duty anti-corrosion in the splash zone and underwater areas of offshore steel structures.

Professional coating technology support services

Kexin has an experienced coating R&D and application team providing full-process support — from substrate analysis, coating selection and process-parameter optimization to on-site application guidance.

Eco-compliant green manufacturing system

All products are certified against the ROHS/REACH environmental regulations and their VOC content meets national environmental standards. Environmental performance test reports issued by authoritative third-party laboratories such as SGS and CTI are provided.

Complete quality control and batch traceability

A full-process quality control system, from incoming raw materials to dispatch of finished goods. Every batch passes rigorous physico-chemical testing and simulated coating trials. Each shipment is released with a batch test report and a product warranty.

TechnicalSpecifications

Basic parameters

Suitable substratesCovers all common substrate types
Coating typesAcrylic / PU / epoxy / UV
Curing methodBaking / air drying / UV curing
Gloss rangeHigh gloss / semi-gloss / matt
Colour optionsPrecise matching in any colour
Industries servedUsed across many industries
Environmental certificationROHS/REACH/GB
Packaging Specs4 L / 20 L drum packaging

Performance

Adhesion (cross-cut)Grade 0–1 (5B)
Pencil hardnessH-2H
Salt spray resistance240-500h
Damp-heat resistanceNo abnormality after 500 h
Perspiration resistantNo abnormality after 48 h
RCA abrasion resistance>200 cycles
Impact resistance50kg·cm
VOC content<420g/L

The technical parameters above are taken from test data of the Kexin New Materials laboratory (ISO 17025 accredited); actual values may differ slightly depending on application conditions and substrate. Please contact technical support to obtain a current COA test report.

Frequently AskedFAQ

Which substrates and scenarios does it suit?+
Suitable for many common substrates, including steel, concrete, wood and plastics. Widely used in industrial manufacturing, architectural decoration, automotive and transport, furniture and home furnishings. For professional selection advice, call 400-901-0757.
What is the application method?+
Apply by conventional spray, brush or roller. Substrate must be clean, dry and grease-free. Ambient temperature 5-35°C, relative humidity <85% 为BestApplicationConditions。SpecificParameters — see Products TDS Technical Data Sheet。
Which primer or topcoat completes the system?+
We recommend using a matching primer and topcoat from the same Kexin series to secure system compatibility and best performance. A Kexin engineer can design a complete primer-midcoat-topcoat system for your specific service conditions, free of charge.
How to get samples and a quote?+
Free samples of standard products are provided (freight at the customer's cost), supplied with TDS and MSDS documentation. For bulk purchases please contact 400-901-0757 or 13531350189. Sample quantity from 1 kg; bulk orders from 20 kg.
How do I pick the right grade for my operating conditions?+
Choosing a coating product requires considering the substrate type, the service environment (temperature / humidity / chemical media), the required corrosion protection class (ISO 12944 C1-C5M), the application conditions and the budget. We recommend contacting our technical engineer on 400-901-0757 for professional selection advice; free trial spraying and test verification are supported.
What is the MOQ and lead time?+
Samples from 1 kg; regular products from 20 kg per batch. Stock items ship within 48 hours, made-to-order products in 3-7 working days. Door delivery can be arranged within the Pearl River Delta region.

ApplicationProcess

1

Surface preparation

Clean substrates thoroughly of oil and rust. Blast steel to Sa2.5. Pre-treat per product spec to keep the substrate clean. Ambient 5-40°C, relative humidity<85%。

2

Primer / pre-treatment

Select the matching primer or pre-treatment per substrate and system. Mix strictly at the stated ratio and control DFT. Proceed after the primer dries; pre-stripe critical areas.

3

Main-coat application

Apply the main coat per the process spec, strictly controlling DFT, temperature/humidity and flash-off to keep the film uniform without sagging or pinholes.

4

Curing process

Cure fully by stoving or by ambient air drying as the product requires. Keep oven temperature uniform within ±5°C and ramp up gradually to avoid coating defects. For ambient-curing grades, ensure adequate ventilation and suitable humidity.

5

Inspection & acceptance

Inspect all parameters: dry film thickness, adhesion, gloss, colour difference and chemical resistance. Full performance testing is carried out against the relevant standards. Only after everything passes are the test report and warranty issued, and the goods are packed and shipped in dust-free conditions.

ApplicationsCases

海上平台玻璃鳞片涂料

Offshore Platform Glass Flake Coating

Epoxy glass flake coating spraying C5-M protection for offshore oil platform steel structures

船舶玻璃鳞片涂料

Marine Glass Flake Coating

Epoxy glass flake coating application for ship ballast tanks and cargo oil tanks

石化储罐玻璃鳞片涂料

Petrochemical Storage Tank Glass Flake Coating

Epoxy glass flake coating application for petrochemical storage tank inner walls, chemical resistant

化工厂玻璃鳞片涂料

Chemical Plant Glass Flake Coatings

Heavy-Duty Anti-Corrosion Spraying of Epoxy Glass Flake Coatings for Steel Structures in Chemical Plants

污水池玻璃鳞片涂料

Sewage Tank Glass Flake Coatings

Acid and Alkali Resistant Epoxy Glass Flake Coatings for Inner Walls of Industrial Sewage Tanks

电厂脱硫玻璃鳞片涂料

Power Plant Desulfurization Glass Flake Coatings

Epoxy Glass Flake Coatings for Power Plant Flue Gas Desulfurization FGD Systems

水闸玻璃鳞片涂料

Sluice Gate Glass Flake Coatings

Epoxy Glass Flake Coating Application for Steel Gates in Water Conservancy Projects

桥梁玻璃鳞片涂料

Bridge Glass Flake Coatings

Epoxy Glass Flake Coating Spraying for Steel Structures of Long-Span Bridges

冷却塔玻璃鳞片涂料

Cooling Tower Glass Flake Coatings

Epoxy Glass Flake Coatings for Steel Structures of Power Plant Cooling Towers

造纸设备玻璃鳞片涂料

Glass flake coating for papermaking equipment

Epoxy glass flake coating for paper mill equipment, moisture-resistant

海洋风电玻璃鳞片涂料

Glass flake coating for offshore wind power

Epoxy glass flake coating for offshore wind foundation structures

钢管桩玻璃鳞片涂料

Glass flake coating for steel pipe piles

Epoxy glass flake coating for port and wharf steel pipe piles in splash zone

Technical documents MSDS (Material Safety Data Sheet) TDS Technical Data Sheet

Epoxy glass flake coating·Factory direct supply

KeXin epoxy glass flake coating direct from source factory. Free sample testing, on-site guidance by technical engineers, ISO-certified quality assurance.

Free sample testing
On-site engineer guidance
Fast dispatch within 48 hours
ISO-certified factory · direct supply

Related articles & news

Further reading: technical articles and industry news from Kexin New Materials