MSDS (Material Safety Data Sheet) – Epoxy Terrazzo Flooring KF-ET500

Material Safety Data Sheet · GB/T 16483-2008 · 16 sections in total

Revision date: 2026-06-08 Version: 1.0 Series: epoxy terrazzo flooring KF-ET500

1 Identification of the substance / mixture and of the company / undertaking

Product Nameepoxy terrazzo flooring KF-ET500
Recommended useEpoxy terrazzo flooring is intended for industrial coating applications related to the epoxy floor coatings category.
Use restrictionsFor indoor flooring application or under sheltered (rain-protected) conditions only. Not for long-term outdoor exposure (epoxy resin is not UV-resistant and yellows). Not for surfaces under continuous high temperature (>80 °C). Antistatic flooring must include a copper-foil grounding system as designed.
ManufacturerKexin New Materials (Guangdong) Co., Ltd.
ProducerFoshan Shunde Mingbang Chemical Industry Co., Ltd.
AddressNo. 19 Shilong Avenue, Xintang Industrial Zone, Lunjiao, Shunde, Foshan, Guangdong
Emergency telephone+86-0757-88793275
Websitehttps://www.psste.com

2 Hazard identification

Signal word: Warning (solvent-free type); Danger (solvent-borne type containing benzyl alcohol or xylene)
🔥GHS02
❗GHS07

Hazard Statements

  • Flam. Liq. 3: H226 Flammable liquid and vapour (solvent-borne; solvent-free exempt)
  • Skin Irrit. 2: H315 Causes skin irritation
  • Eye Irrit. 2: H319 Causes serious eye irritation
  • Skin Sens. 1: H317 May cause an allergic skin reaction
  • STOT SE 3: H336 May cause drowsiness or dizziness (solvent-borne)
  • Aquatic Chronic 3: H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P210: Keep away from heat sources and open flames (Solvent type).
  • P261: Avoid breathing vapours/dust.
  • P280: Wear protective gloves / eye protection / protective clothing.
  • P302+P352: If on skin: wash with plenty of soap and water.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P333+P313: If skin irritation or rash occurs: get medical advice/attention.
  • P501: Send the waste to a hazardous waste treatment facility.

3 Composition / information on ingredients

Chemical substanceCAS No.Concentration rangeGHS classification
Epoxy resin (bisphenol-A / epichlorohydrin resin, liquid type, MW 340-700)25068-38-630-50% (solvent-free binder) / 25-40% (solvent-borne) / 40-60% (water-based)Skin Irrit. 2 (H315), Eye Irrit. 2 (H319), Skin Sens. 1 (H317)
Modified cycloaliphatic amine hardener (Modified cycloaliphatic amine / Mannich base hardener)2855-13-2 (Isophoronediamine, IPDA, typical component); 1761-71-3 (4,4'-Diaminodicyclohexylmethane, PACM)Component B: 40-65%Acute Tox. 4 (H302+H312), Skin Corr. 1B (H314), Eye Dam. 1 (H318), Skin Sens. 1 (H317), Aquatic Chronic 3 (H412)
苯甲醇 (Benzyl alcohol)100-51-65-15% (in solvent-free formulations, as reactive diluent and cure accelerator)Acute Tox. 4 (H302+H332), Eye Irrit. 2 (H319)
Reactive diluent (C12-C14 alkyl glycidyl ether / AGE, aliphatic monoglycidyl ether)68609-97-2 (C12/C14 AGE); 2461-15-6 (2-Ethylhexyl glycidyl ether)5-15% (solvent-free formulation)Skin Irrit. 2 (H315), Eye Irrit. 2 (H319), Skin Sens. 1 (H317)
Quartz sand / microsilica (crystalline silica filler)14808-60-7 (α-Quartz)20-60% (filler, depending on product type — self-levelling contains 20-40%, mortar contains 40-60%)STOT RE 1 (H372): Inhalation of respirable crystalline silica dust can cause silicosis — however, in the coating the quartz is in a wet state / bound in the cured matrix, and normal use does not generate respirable dust. Sanding cured flooring may produce dust containing crystalline silica — respiratory protection is required.
Pigments/colour pastes (TiO₂ + organic/inorganic pigments)13463-67-7 (TiO₂)1-5%No significant GHS classification (paste/liquid form as used)

4 First-aid measures

Inhalation

Move the casualty to fresh air immediately. If breathing is difficult, give oxygen. Seek medical attention immediately. Note: amine hardener vapours/aerosols are strongly irritating to the respiratory tract.

Skin contact

Immediately remove all contaminated clothing. Wash thoroughly with plenty of running water and soap for at least 15 minutes. Amine curing agents can cause skin corrosion/severe irritation - washing must be prompt and thorough. If irritation persists, seek medical advice.

Eye contact

Immediately flush with plenty of water for at least 15-20 minutes, holding the eyelids open. Amine curing agents can cause serious eye damage! Seek medical advice immediately, preferably an ophthalmologist.

Ingestion

Rinse mouth with water (if conscious). Do not induce vomiting. Seek medical attention immediately.

Most important symptoms and effects:Amine hardener: skin contact can cause severe pain, redness, blisters and chemical burns (alkali burns). Eye contact — severe pain, risk of corneal damage. Epoxy resin: skin sensitisation — erythema, itching, rash. Inhalation of hardener aerosol — coughing, breathing difficulty, burning sensation in the throat.

Conditions requiring immediate medical attention:Amine burns: rinsing with plenty of water is the critical first step. Doctor: symptomatic treatment. No specific antidote. Persons allergic to epoxy resin should avoid re-exposure.

5 Fire-fighting measures

Suitable extinguishing mediaCarbon dioxide, dry powder, foam, water mist.
Unsuitable extinguishing mediaDirect water jet.
Specific hazardsCombustion produces CO, CO₂, NOx, ammonia (amine hardener). Closed containers may rupture when heated.
Special protective equipment for firefightersFirefighters: self-contained breathing apparatus (SCBA) plus full protective clothing.

Contain and collect fire-fighting run-off.

6 Spill release measures

Operator protection:Wear full PPE (pay special attention to corrosion-resistant gloves and goggles, as the product contains amine hardener). Remove ignition sources. Ensure adequate ventilation.

Environmental precautions:Prevent entry into sewers and water bodies. Amines are highly toxic to aquatic life.

Containment and cleaning methods:Small spill: absorb with absorbent material (sand, vermiculite). Large spill: dike to contain and recover using an explosion-proof pump. Clean contaminated surfaces with diluted acetic acid solution (5%) or citric acid solution to neutralise, then rinse with plenty of water. Regular coating spills can be cleaned with solvent (e.g. xylene or a dedicated thinner).

7 Handling and storage

Precautions for safe handling

Operate in a well-ventilated area. Even solvent-free products still contain a small amount of volatile organic compounds (e.g. benzyl alcohol). When handling the amine hardener, note: it is corrosive — avoid any skin contact. Mixing the epoxy resin and hardener produces an exothermic reaction — mix only as much as can be used within the pot life (typically 20-40 min @ 25°C), and immediately spread the mixture out on the floor after mixing (a thin layer dissipates heat quickly); do not leave it in the bucket for long periods (this can cause the bucket to overheat or even smoke). When applying anti-static flooring, the grounding copper foil must be laid at the same time.

Storage Conditions

Store cool and dry at 5-35°C. Keep Components A and B strictly separated. Keep hardener containers tightly sealed (amines react with airborne CO₂ to form carbamate precipitate — white bloom). Shelf life: 12 months (original sealed packaging). Solvent-free flooring coatings may crystallize at low temperatures (below 5°C) — warm them to dissolve the crystals before use.

8 Exposure controls / personal protection

substancePC-TWAPC-STELStandard
苯甲醇10 mg/m³ (not listed in GB; ref. MAK value)20 mg/m³DFG MAK Commission (Germany)
Crystalline silica (inhalable dust, respirable)0.05 mg/m³ (PC-TWA, RCS)—GBZ 2.1-2019 (relevant for grinding cured epoxy floors)
Isophorone diamine (IPDA, vapour)3 mg/m³ (reference value)6 mg/m³Not listed in GB; refer to Swiss SUVA OEL

Engineering controls

General ventilation plus local exhaust ventilation. Forced ventilation is required for large-volume application. When sanding cured flooring: use an industrial vacuum with high-efficiency filtration (H13 HEPA) or a wet-grinding process - to reduce the airborne concentration of inhalable crystalline silica dust.

Personal Protective Equipment (PPE)

Respiratory systemNormal application: half-mask with organic vapour/particulate combination filter (A2P2). Sanding flooring: at least a P3 particulate-filter half-mask (for crystalline silica dust); for heavy sanding use a powered air-purifying respirator (PAPR). Amine curing agent handling: full-face organic vapour cartridge.
Hand protectionButyl rubber gloves or thick nitrile rubber (≥0.5 mm) gloves - amine curing agents can quickly penetrate thin gloves. Do not use natural latex gloves. Two layers of gloves are recommended (disposable inner layer + thick outer layer).
Eye protectionChemical splash goggles + face shield. Mandatory when handling the amine hardener.
Skin and bodyChemical-resistant protective clothing. Long sleeves and trousers. Safety shoes. Change and wash contaminated clothing immediately.

9 Physical and chemical properties

AppearanceViscous liquid in various colours (self-levelling); filled paste form (mortar/terrazzo)
OdorSlight amine odour (solvent-free type) or characteristic solvent odour (solvent-borne type)
pH valueNot applicable (organic system)
Flash Point>100°C (solvent-free, closed cup, ASTM D56); approx. 25-35°C (solventborne)
Relative Density1.1-1.8 g/cm³ (depending on filler content)
SolubilityInsoluble in water; soluble in ketone/ester/aromatic hydrocarbon solvents (uncured state)
ViscositySelf-levelling: approx. 600-1,200 mPa·s (25°C, Brookfield); mortar trowel grade: >5,000 mPa·s (thixotropic)
Solids contentSolvent-free: 95-100%; solvent-borne: 55-70%; water-based: 50-65%
VOC contentSolvent-free: <60 g/L; solventborne: <400 g/L; waterborne: <100 g/L

10 Stability and reactivity

ReactivityMixing epoxy + amine triggers an exothermic polymerisation reaction. In large batches the heat release can raise the temperature above 150°C — risk of self-accelerating decomposition.
Chemical stabilityStable under recommended conditions.
Possibility of hazardous reactionsLeaving a large mixed batch in the drum: exotherm -> rising temperature -> accelerated reaction -> more heat -> thermal runaway -> the drum may smoke, swell or even rupture. This is one of the greatest safety hazards in epoxy flooring application.
Conditions to avoidHigh temperature (accelerates the exothermic reaction). Large mixed quantities kept sealed. Mixed material left standing without being spread out. Contact of the hardener with moisture/CO₂.
Incompatible materialsStrong oxidizers, strong acids. The amine hardener generally does not react violently with chemicals other than epoxy, but reacts slowly with water and CO₂.
Hazardous decomposition productsCombustion: CO, CO₂, NOx, ammonia, amine compounds. Thermal decomposition (>200°C): phenols, bisphenol A.

11 Toxicological information

Acute Toxicity

Routes of exposureindicatorTest species
oral ld50>2,000 mg/kg (mixture, rat); amine hardener: LD₅₀ oral rat = 500-2,000 mg/kg (Category 4)
dermal ld50胺Curing Agent: LD₅₀ dermal rabbit > 1,000-2,000 mg/kg (Category4)
inhalation lc50No significant acute inhalation toxicity (mixture ATE calculated from components > 5 mg/L/4h)

Other toxicological information

Skin corrosion / irritationAmine hardeners can cause skin corrosion/serious irritation (H314 Category 1B). Epoxy resin binders cause skin irritation (H315).
Serious eye damage/eye irritation胺Curing Agent——Serious eye damage/eye irritation(H318Category1)。EpoxyBinder——眼刺激(H319)。
May cause allergy from inhalation or skin contactepoxy resin(MW<700)是已知skin sensitisers(H317)。胺Curing Agent也可能引起皮肤过敏。对epoxy resin过敏者通常在接触后24-72 hours出现症状。
CarcinogenicityCrystalline silica (quartz-sand filler) - IARC Group 1 (carcinogenic to humans), but this classification applies only to occupational exposure to inhalable crystalline silica dust (e.g. blasting, mining, stone processing). In the liquid/wet use of epoxy flooring coatings or in the fully cured coating, crystalline silica does not give rise to inhalable dust exposure. If dust is generated when sanding cured flooring - there is an exposure risk and appropriate respiratory protection must be worn. Epoxy resin and amine curing agents are not classified as carcinogenic.
Specific target organ toxicity - single exposureAmine hardener vapours/aerosols can irritate the respiratory tract (H335). Solvent-borne type contains solvent — may cause drowsiness/dizziness (H336).
Specific target organ toxicity - repeated exposureLong-term inhalation of respirable crystalline silica dust can cause silicosis (pulmonary fibrosis) and an increased risk of lung cancer (H372). This hazard applies only to dust-exposure scenarios during sanding.
Aspiration hazardSolvent-borne formulation: swallowing and entry into the respiratory tract may be fatal (contains solvent). Solvent-free type: high viscosity, inhalation risk relatively low.

12 Ecological information

Ecotoxicity

Speciesindicator
fish 96h lc50胺Curing Agent: LC₅₀ (fish) = 10-100 mg/L; epoxy resin: LC₅₀ > 100 mg/L
daphnia 48h ec50胺Curing Agent: EC₅₀ (Daphnia) = 1-10 mg/L
algae 72h ec50EC₅₀ (algae) = 1-10 mg/L (amine hardener)

Persistence and degradability

Epoxy resin is not readily biodegradable. The amine hardener is partially biodegradable (OECD 301: 20-60% in 28 d). Cured epoxy flooring is a highly stable thermoset plastic that degrades extremely slowly in the environment.

Bioaccumulative potential

Epoxy resin and amine hardener: high molecular weight / high polarity, low bioavailability, no significant bioaccumulation.

Mobility in soil

Uncured epoxy and amines have medium-to-low mobility in soil. Once cured, they are completely immobile (solid plastic).

Other adverse effects

Amines are toxic to aquatic life (Category 3). Do not discharge uncured product or washing water into water bodies. The fully cured flooring coating is inert to the environment.

13 Disposal

Disposal method:Liquid paint waste: HW12 (900-299-12). Waste hardener: HW12/HW06. Recommendation: send to a licensed hazardous waste incineration plant. Cured epoxy flooring solid waste (demolition waste): may be disposed of as construction waste / general industrial solid waste (fully cured epoxy resin is an inert solid), but confirm the classification guidance of the local environmental protection authority.

Contaminated packaging disposal:Non-emptied containers: hazardous waste (HW49). Emptied containers: metal for recycling; plastic via hazardous waste disposal. Empty hardener pails: do not rinse with water (spreads contamination) — rinse with a small amount of solvent (alcohol) and add the recovered rinse liquid to the next paint batch, or dispose of the empty pail directly as hazardous waste.

14 Transport Info

UN No.UN3082 (Environmentally hazardous substance, liquid, n.o.s., containing amine curing agent) or UN1263 (Solvent type). Solvent-free epoxy flooring: most formulations are not dangerous goods (flash point >93 °C, not environmentally hazardous).
Proper shipping nameEnvironmentally hazardous substance, liquid, n.o.s. (Amine hardener) or Not regulated (solvent-free binder)
Transport hazard class第9类 (UN3082) 或 Not regulated
Packing groupPG III (when regulated)
Environmental HazardsAmine hardener: yes (marine pollutant, aquatic chronic category 3). Solvent-free epoxy resin binder is generally not a marine pollutant.
Special precautionsProtect the amine hardener from moisture and sunlight during transport.

15 Regulatory Info

Chinese regulations

  • GB/T 16483-2008
  • GB 30000-2013
  • GBZ 2.1-2019
  • GB/T 50589-2010 Technical code for epoxy resin self-leveling flooring
  • GB 50209-2010 Code for quality acceptance of building floor construction
  • GB/T 22374-2018 Floor coating materials (product standard)
  • Catalogue of Hazardous Chemicals (2015 edition) — the amine hardener-related ingredients are listed
  • GB 18581-2020 Limits of harmful substances in wood coatings (refer to VOC limits for solvent-free/waterborne systems)

International regulations

  • EU REACH (EC) No 1907/2006
  • EU CLP (EC) No 1272/2008
  • US OSHA HazCom 2012
  • RoHS 2011/65/EU — standard epoxy floor coating formulations are compliant
  • AgBB / DIBt (German Committee for Health-Related Evaluation of Building Products) — applicable when solvent-free/waterborne epoxy flooring is used in interior buildings.

16 Other information

Revision date:2026-06-08

Version:1.0

References

  • ECHA Registered Substances Database (echa.europa.eu)
  • NIOSH Pocket Guide to Chemical Hazards (cdc.gov/niosh/npg)
  • PubChem Compound Database (pubchem.ncbi.nlm.nih.gov)
  • GBZ 2.1-2019 Occupational exposure limits for hazardous agents in the workplace — Chemical hazardous agents
  • GBZ/T 195-2007 Occupational health management specification for workplaces using organic solvents
  • IARC Monographs on the Evaluation of Carcinogenic Risks to Humans

Abbreviations

GHS: Globally Harmonized System of Classification and Labelling of Chemicals; PC-TWA: Permissible Concentration-Time Weighted Average; PC-STEL: Short Term Exposure Limit; OEL: Occupational Exposure Limit; PPE: Personal Protective Equipment; LD₅₀: Lethal Dose 50%; LC₅₀: Lethal Concentration 50%; EC₅₀: Effect Concentration 50%; BCF: Bioconcentration Factor; Kow: Octanol-Water Partition Coefficient; SCBA: Self-Contained Breathing Apparatus; PBT: Persistent, Bioaccumulative and Toxic; vPvB: very Persistent and very Bioaccumulative; COA: Certificate of Analysis

Disclaimer:This MSDS was compiled from public chemical databases such as ECHA, NIOSH and PubChem together with typical industry formulations, and is for reference only. CAS numbers have been verified against public databases. The exact proportion of each component is a core technology secret of the plant, so this document states typical industry concentration ranges. Actual data shall be taken from the plant batch test report and the Certificate of Analysis (COA). Kexin New Materials assumes no legal liability arising from use of the information in this MSDS. Users shall assess the suitability and safety of the product under their own specific conditions of use and comply with all applicable local laws and regulations. This document was compiled in accordance with GB/T 16483-2008 and comprises 16 sections.

⬇ Download this document (PDF)

Related articles & news

Further reading: technical articles and industry news from Kexin New Materials